The UK Greenhouse Heat-Loss & Wattage Formula
Multiply your greenhouse's total glazed wall and roof area (in m²) by your target temperature lift (ΔT in °C, such as lifting −5°C outside up to +5°C inside = 10°C lift) and the glazing heat-loss factor (~6.2 W/m²°C for unlined single glass, or ~3.8 W/m²°C when lined with bubble wrap):
Watts Needed = Total Glazed Area (m²) × Temp Lift (°C) × Glazing Factor (6.2 or 3.8)
A standard 8ft × 6ft (2.4m × 1.8m) single-glazed greenhouse (~21 m² glass area) holding a 10°C lift needs 1,300W unlined—or just 800W when lined with horticultural bubble wrap (comfortably covered by a 1.5kW–2kW thermostatic fan heater).
Calculate exact heater wattage, BTU, and insulation savings for your greenhouse dimensions using our Greenhouse Heater Wattage & BTU Calculator.
Quick-Lookup UK Greenhouse Size to Heater Wattage Chart (10°C Frost Lift)
| UK Greenhouse Size | Approx. Glazed Area | Unlined Single Glass | Bubble-Wrap Lined | Recommended Heater Size |
|---|---|---|---|---|
| 6ft × 4ft (1.8m × 1.2m) | ~14 m² | 870 W | 530 W | 1.0kW–1.5kW fan heater |
| 8ft × 6ft (2.4m × 1.8m) | ~21 m² | 1,300 W | 800 W | 1.5kW–2.0kW fan heater |
| 10ft × 8ft (3.0m × 2.4m) | ~30 m² | 1,860 W | 1,140 W | 2.0kW–2.8kW fan heater |
| 12ft × 8ft (3.6m × 2.4m) | ~35 m² | 2,170 W | 1,330 W | 2.5kW–3.0kW fan heater |
Useful Greenhouse Heating & Monitoring Gear
2kW Stainless Steel Splash-Proof Greenhouse Fan Heater
IPX4-rated thermostatic electric greenhouse heater with air-circulation fan mode.
Digital Max-Min Greenhouse Thermometer & Hygrometer
Records overnight minimum frost temperatures and daytime peak humidity inside the greenhouse.
135W Waterproof Greenhouse Tubular Heater with Guard
Low-wattage background frost-protection bar for cold frames and small 6×4 greenhouses.